PAC Metal Roofing Panels used to replace a badly leaking architectural shingle roof at Northwest Arkansas Community College in Bentonville, AR. “We get lots of wind in the area and every time a storm would come through, we would lose shingles,” said Jim Lay, construction manager for the college. “So in our master plan, we decided to use metal on all future roof installations.”
Approximately 100,000 sq. ft. of PAC-CLAD Snap-Clad Panels were used in the major tear-off and re-roof project. The 24 gauge, 18” panels were finished in Forest Green.
Project design for the 189,000 building was provided by MAHG Architecture, Inc., Fort Smith, AR. According to partner Galen Hunter, “The school saw this as an opportunity to resolve the leakage problem and bring the building into conformance with the master plan. The re-roof was done in sections while classes were in session and the whole process went smoothly. We’ve spent a lot of time researching roofs and we’re very confident with the Petersen system.”
Installation of the roof was done by Harness Roofing, Inc., Springdale, AR. “The school originally wanted a metal roof when the building was constructed 15 years ago but opted for a less expensive shingle roof that failed,” said James Russell, project manager. “The building had been well maintained and adding the metal roof made it look like new. The only challenge was working around the students. We had to keep moving safety fences and equipment. And, of course, we had to remain covered-up and water tight at all times. But the building really got a modern facelift and looks great.”
Petersen Metal Roof Panels Selected to Retrofit Community College Roof
PAC Metal Roofing Panels used to replace a badly leaking architectural shingle roof at Northwest Arkansas Community College in Bentonville, AR. “We get lots of wind in the area and every time a storm would come through, we would lose shingles,” said Jim Lay, construction manager for the college. “So in our master plan, we decided to use metal on all future roof installations.”
Approximately 100,000 sq. ft. of PAC-CLAD Snap-Clad Panels were used in the major tear-off and re-roof project. The 24 gauge, 18” panels were finished in Forest Green.
Project design for the 189,000 building was provided by MAHG Architecture, Inc., Fort Smith, AR. According to partner Galen Hunter, “The school saw this as an opportunity to resolve the leakage problem and bring the building into conformance with the master plan. The re-roof was done in sections while classes were in session and the whole process went smoothly. We’ve spent a lot of time researching roofs and we’re very confident with the Petersen system.”
Installation of the roof was done by Harness Roofing, Inc., Springdale, AR. “The school originally wanted a metal roof when the building was constructed 15 years ago but opted for a less expensive shingle roof that failed,” said James Russell, project manager. “The building had been well maintained and adding the metal roof made it look like new. The only challenge was working around the students. We had to keep moving safety fences and equipment. And, of course, we had to remain covered-up and water tight at all times. But the building really got a modern facelift and looks great.”
This entry was written by Balcom Vetillo, posted on November 5, 2009 at 5:19 pm, filed under Metal Roofing and tagged metal roof, Metal Roofing, metal standing seam roofing, Northwest Arkansas Community College, PAC-CLAD, PAC-CLAD Panels, Petersen Metal Products, roof installations, Snap-Clad metal roofing. Bookmark the permalink. Follow any comments here with the RSS feed for this post.
Post a comment or leave a trackback: Trackback URL.