PAC-CLAD Integral Panels are designed for roofing applications, mansards, canopies and fascia. The one-piece design of the Integral Panels minimizes labor and allows for quick and easy installation. Integral panels are to be factory roll formed in continuous lengths (minimum panel length is 4 feet).

Standard on-center dimensions are 11”, 18" and 19", but for renovation projects or additions, on-center dimensions may be custom matched to your requirements. Neoprene panel closures are available for installation at the eave.

UL 90 Classified
Steel PAC-CLAD Integral Panels carry a UL 90 Classification for wind uplift when fastened to an underlayment assembly including 5/8” plywood or OSB laminated to rigid insulation. (UL Construction No. 346 & 347) For further details contact Petersen Aluminum Corp.

Air and Water Infiltration
Petersen Integral Panels meet the full performance requirements of the ASTM E 283 air infiltration test and the ASTM E 331 water penetration test when applied over a solid substrate. For complete test results, contact Petersen Aluminum Corporation.

Materials
a) 24 ga. G-90 hot-dipped galvanized steel
b) .032 3105-H14 aluminum or equal

Fasteners
For roofing applications, use Petersen non-penetrating clips. Clips shall be 606l-T6 extruded aluminum, fastened on 18" centers. Use wood-type screws in fastening clips. For fascia and mansard applications, panels should be positively fastened to the substrate.

Trim
All flashing and trim will be fabricated by manufacturer or qualified fabricator. Flashing shall be PAC-CLAD aluminum (.032-.080 gauge as specified) or PAC-CLAD 24 ga. steel. A 20 year warranty shall be supplied covering finish performance.

Installation
Roofing Applications: PAC-CLAD Integral Seam Panels shall be installed over solid decking (5/8" plywood, nailboard insulation or equal) with an underlayment of 30# (min.) roofing felt applied horizontally from eave to ridge. Panels shall be fastened using Petersen non-penetrating clips, fastened on 18" centers (max.). Minimum slope at 3:12 pitch. Consult a local architect/engineer for requirements of local codes and conditions.

Petersen Aluminum Corporation
Elk Grove Village, IL Annapolis Junction, MD Tyler, TX Kennesaw, GA    Fridley, MN
Phone: 800-PAC-CLAD    info@pac-clad.com
Herr-Voss
corrective leveled
Labor-saving one-piece design
Stiffener beads available
   
MATERIAL
42 standard
colors (steel)
37 standard colors (aluminum)
Smooth and
stucco embossed available
20 year non-pro rated finish
warranty
Galvalume Plus available
   
UL
CLASSIFICATION
UL-580 Class 90 rated over solid substratrate (steel only)
UL-790 Class A fire rated
UL-263 fire
resist ance rated
UL-2218 impact
resistance rated
Wind load testing results available
   
ASTM TESTS
ASTM E283 tested
ASTM E331 tested
*24 ga. panels listed in bold print are UL-90 Classified over solid substrate. See roof deck construction in Underwriter Laboratories roofing materials and
systems directory.