Section 07400
A. Standing Seam Metal Roof Manufacturer and Contractor shall be responsible for manufacturing and installing BIPV Standing Seam Roof Panel per drawings for a (5kw, 10kw, 15kw, 30kw, 60kw, or 120kw) PV System. Electrical work to be by Electrical Contractor per Spec Section 48-14-00
B. Related Specs – Section 48-14-00 Photovoltaic System
C. Products –
D. The Standing Seam Roof Manufacturer shall coordinate with the Architect on locations and appearance of all BIPV Standing Seam Panels and Ridge and/or Mid Roof cable trays. All locations must be approved by the Architect prior to installation.
E. Fall arrest protection per OSHA 1926 Subpart M shall be provided for all work on top of BIPV Standing Seam Roof and Standing Seam Contractor shall offer safe protection to Electrical Contractor to connect BIPV module connectors in the Ridge and / or Mid Roof cable trays.
F. The Standing Seam Metal Roof Contractor shall notify the Construction Manager a minimum of 5 days before closing in of Ridge Cap and / or Mid Roof cable trays so the Electrical Contractor can be notified to complete wiring on roof.
G. Warranty – The Standing Seam Roof Contractor provide a 20 year warranty on the electrical performance of the PV modules, and warrant that the BIPV Standing Seam Panels will be free from manufacturing defects.