PAC ECO Vented Fascia

PAC ECO Vented Fascia

Features
  • Provides outstanding roof ventilation at exposed trusses
  • Minimum 12 square inches per foot NFA
  • 2-component system installs easily
  • Perforated closures provide 51% NFA
  • Prevents heat build-up and moisture accumulation
  • Optional cover available in variety of gauges and colors
  • Four adjustable lengths available

Petersen Aluminum offers its line of Airflow systems, designed specifically with commercial buildings in mind. Highly suitable for both shingle and metal roofs, the system allows for balanced intake and exhaust ventilation to provide optimal airflow, greatly increasing the roof’s longevity and energy efficiency.

 

Petersen offers a complete line of ventilation products, which in unison, provide consistent airflow under the roof covering:

  • PAC SS Vented Eave
  • PAC ECO Vented Fascia
  • PAC SS Rake Fascia/Rake Panel
  • PAC SS Ridge Vent

PAC ECO Vented Fascia

Highly suitable for projects with exposed trusses, the PAC ECO Vented Fascia is highly functional in systems with or without soffits. By calculating the project’s specific net free area (NFA) requirements, PAC ECO Vented Fascia allows the precise amount of airflow in between the trusses for superior system ventilation.

 

PAC ECO Vented Fascia provides an unmatched minimum NFA of 12 square inches per lineal foot to maximize the intake airflow at the eave. By providing this maximum airflow under the roof covering, heat build-up and moisture accumulation is prevented. This results in added longevity to the roof system.

 

The highly efficient design features 24 GA steel mounting brackets and perforated closures, available in four adjustable sizes to ensure a precise fit on any roof condition. The multiple size capability also eliminates the need for wood blocking for additional cost and labor savings. Pre-slotted holes allow accurate fastener placement.

 

Importance of Ventilation

Plain and simple, proper airflow designed into the roof structure will extend the life of the roof. Premature re-roofing is expensive, and inconvenient to the building occupants. Without consistent and balanced airflow and proper NFA, moisture build-up will occur, which can damage the roof covering over time. Temperature fluctuations will cause snow melting and refreezing, resulting in ice dams on the roof that can cause structural damage as well as hazards to life and property on the ground.

 

In addition, providing constant air movement prevents heat build-up in the summer and heat loss in the winter, resulting in a more sustainable building with lower operating costs.

 

PAC Airflow systems, designed specifically for ventilation needs at the eave and the ridge of each project, contribute to the green roof system for superior sustainability and life-cycle value.

 

 

Snap-Clad Panel
Tite-Loc Panel
Tite-Loc Plus Panel
Tite-Loc HS Panel
Snap-On Standing Seam Panel
High Snap-On Standing Seam Panel
Snap-On Batten Panel
Redi-Roof Standing Seam Panel
Redi-Roof Batten Panel
Integral Standing Seam Panel
Integral Batten Panel
Edge-Loc Panel
Colorguard™ Snow Guards
M-42 & M-36 Panels
7.2 Panel
1/2″ & 7/8″ Corrugated Panel
R-41 & R-36 Panels
Flat and Coil Stock
Flashing and Trim
Custom Fabrication
Anodized Aluminum
Acrylic Aluminum
Copper & Stainless Steel
PAC-750 Soffit
PAC-850 Soffit
Flush/Reveal Soffit
PAC-1000F Column Cover
PAC-1000C Column Cover
PAC-1000R Column Cover
PAC-2000F Column Cover
PAC-2000C Column Cover
PAC-2000R Column Cover
PAC SS Vented Eave & Intake Vent
PAC ECO Vented Fascia
PAC SS Rake Panel & Fascia
PAC SS Ridge Vents
PAC-TITE Angular Fascia
PAC-TITE WT Canted Fascia
PAC-TITE WT Fascia
PAC-TITE WT Extended Fascia
PAC-LOC Fascia
PAC Snap Edge Fascia
PAC Extended Snap Edge Fascia
PAC-TITE Coping
PAC Anchor-Tite Coping
PAC-Continuous Cleat Coping
PAC Precision Series
Composite Wall Panels
Flush/Reveal Wall Panels